Hydromechanical Grease Interceptor
Service for the compact, flow-rated interceptors that use internal baffling and a flow control device to separate grease in seconds instead of relying on a large holding volume.

Kitchens with no room or no permission for an in-ground structure: tenant spaces in malls and mixed-use buildings, upper-floor restaurants, hospital and hotel sub-kitchens, coffee and quick-service builds, and remodels where the plumbing inspector called for a rated unit at the fixture.
How a job runs, step by step
Confirm what unit you actually have
Make, rated flow in gallons per minute, grease capacity in pounds, and whether the flow control device is still installed. That last one is missing more often than anybody expects.
Read the load before opening
Grease depth and solids depth, recorded. On a flow-rated unit these numbers are read against a pound rating rather than a percentage of a tank, which is a different calculation.
Empty it completely
Grease, liquid and the solids on the floor. These units have small internal volumes and a partial service costs you most of the interval.
Clean the internals and the air relief
Baffles, the diffuser, the removable internal parts and the air intake or relief path all get cleaned. A blocked air relief on a hydromechanical unit changes how it behaves under flow.
Check the flow control device
The orifice and vent get inspected and cleared. A restrictor that has been removed, bypassed or plugged is the single most common reason one of these units stops separating.
Reassemble, test and document
Cover and gasket reseated, a flow test through the fixture, then the manifest, disposal record and photos.
Rated by flow, not by volume, and that changes everything
This is the distinction that matters and it is the one nobody explains to the operator. A gravity interceptor separates grease by holding a large volume of water still for a long time. A hydromechanical unit cannot do that, because it is the size of a small chest and lives under a sink. Instead it manufactures separation with internal geometry: a flow control device meters the incoming water to a fixed rate, baffles and a diffuser turn the flow so it slows and spreads, air is introduced so grease is buoyed upward, and the whole exchange has to happen in seconds rather than minutes. That is why these units carry two numbers instead of one. There is a rated flow in gallons per minute, which is the fastest water can arrive and still be separated, and there is a grease capacity in pounds, which is how much accumulated grease the unit can hold before it stops working. Both matter and they fail differently. Exceed the pounds and the unit is simply full, which looks like what everybody expects a full trap to look like. Exceed the rated flow and the unit passes grease straight through while sitting nearly empty, because the water never slowed down enough for anything to rise. An operator who only understands full and not full will read the second failure as a healthy trap.
The flow control device is not optional and it is usually gone
Every hydromechanical unit is certified as a system, and the flow control device is part of the system. It is a small fitting on the inlet side with a fixed orifice and a vent, and its entire job is to guarantee that the unit never sees more gallons per minute than it was rated for, no matter how fast the sink drains or how hard the dish machine dumps. Without it, a three compartment sink emptying under a full head of water can hit a small unit with several times its rated flow in a few seconds, and the interceptor becomes a pipe with a lid on it. The device goes missing constantly. Somebody pulls it during a slow-drain complaint and never puts it back, because removing it does make the sink drain faster and nothing visibly bad happens that day. A remodel plumber leaves it out. It plugs with debris and gets discarded rather than cleaned. The vent on it gets sealed or buried, which defeats the orifice just as thoroughly as removing the fitting. So we look for it every visit, and when it is not there, that gets reported before anything else, because a shorter service interval will not compensate for a unit running unrestricted. It is the closest thing to a single point of failure these units have.
Where they get installed, and what that costs you in access
Hydromechanical units exist because a lot of kitchens have nowhere to put a structure in the ground. A restaurant on the third floor of a mixed-use building, a food court tenant with no exterior wall, a hospital sub-kitchen in the middle of a floor plate, a build-out in a historic building where nobody is excavating anything. The unit goes indoors, at or near the fixture, sometimes recessed into the floor with a cover flush to the tile, sometimes on the floor beside the sink, occasionally suspended. Each of those has its own service problem. A floor-recessed unit in a finished kitchen means the cover and the surrounding tile have to survive the visit, and the gasket seal on that cover is the only thing between the kitchen and the trap’s headspace. An on-floor unit is easier to open and harder to reach behind. Indoor units also put odor control in a different category from an outdoor interceptor, since there is no dirt and no distance between the contents and the people working the line. That is why a flattened cover gasket or a missing hold-down bolt on one of these is a real finding and not a note at the bottom of a report. We check the seal every visit and we report it in writing when it is going.
Servicing them well, and the numbers worth keeping
The unit gets emptied to the floor, the removable internals come out and get scraped and rinsed, the baffles and the diffuser get cleaned, the air path gets checked, the flow control orifice and vent get inspected and cleared, and the cover goes back with a gasket that seals. Then somebody runs water through the fixture and watches, which takes a minute and catches problems that an empty unit will not show you. What we hand back is the load reading against the unit’s actual pound rating rather than a percentage of a tank, because that is the number that means something on a flow-rated unit, plus photos, the manifest and the disposal record. Kept over a few visits, those readings tell you whether the unit still matches the kitchen. Hydromechanical interceptors are sized against the fixtures they serve at the moment of design, and kitchens change faster than plumbing does. A unit that was correct for the original build and is now taking a dish machine that arrived two years later is a unit that will keep disappointing you, and the honest answer in that case is a sizing conversation, not a tighter schedule. Call 305-761-4311 and we will look at what is under your sink and tell you straight which one you have.
Worth knowing
Ask whoever services your unit to show you the flow control device. If they cannot find it, it is not there, and the unit has probably been running unrestricted for a long time. That single missing fitting undoes the entire reason a hydromechanical interceptor works, and no interval compensates for it.
Ask any contractor where what they pump out actually goes. It is a fair question, and the answer tells you a lot.
VacRite
Other grease work
The other side of the company
Most of our customers only ever need one half of what we do. It is worth knowing the other half exists.
Something failed tonight. Somebody answers.
Struck line, blocked kitchen drain, a basin backing up in the middle of a storm. We run every day of the year, and the phone reaches a person rather than a queue. This company is first responder owned, and the emergency side of it works the way that suggests.

Questions we get asked
What makes an interceptor hydromechanical?
It separates grease using internal baffling, a flow control device and introduced air, in seconds, rather than by holding a large volume of water still for minutes. That is why it can be small enough to fit under a sink.
What is the flow control device for?
It meters the water entering the unit so the unit never sees more gallons per minute than it is rated for. Without it, a sink draining fast overwhelms the interceptor and grease passes straight through, even though the unit looks nearly empty when you open it.
Ours is rated in pounds. What does that mean?
Grease capacity. It is how much accumulated grease the unit can hold before it stops separating. It is a different measure from an in-ground interceptor, which is rated by liquid volume and serviced at a quarter of capacity.
Can a hydromechanical unit replace an in-ground interceptor?
Sometimes, and it depends on the fixtures, the flow and what the authority having jurisdiction accepts for your occupancy. It is a plumbing and code question, and we have a master plumber on staff to look at it rather than a guess over the phone.
How often do these need cleaning?
Generally more often than a large in-ground structure, because the holding capacity is much smaller. What actually sets the interval is your grease load against the unit’s pound rating, which we read on each visit and use to tune the schedule.
Ours is recessed into the kitchen floor. Is that a problem to service?
No, it is a common install. It does mean the cover, the gasket and the surrounding floor get treated carefully, and it means the gasket seal matters more than it would outdoors, because the only thing between the kitchen and the trap headspace is that cover.
Why does our unit keep passing grease when it is barely full?
That is the flow signature, not the capacity signature. Either the flow control device is missing, plugged or vented shut, or the fixtures draining into the unit now send more water than it was rated for. Cleaning it more often will not change either one.
We run hydromechanical grease interceptor across South Florida, including Miami, Fort Lauderdale, West Palm Beach, and the rest of the region. See every city we cover or look at the trucks on the job.
Tell us what the job is
Tell us about the hydromechanical grease interceptor job. Where it is, what is around it, and when you need it.
Two trades, one call. We own the trucks, hold the permits, and put our own people on the job.